18 inch slab decking 2 pannel square

Vulcraft Steel Deck Catalog - NYIT Structural Steel Design

The 29-story First Indiana Plaza in downtown Indianapolis used. 439,440 square feet of Vulcraft 3 composite deck. Developer: Duke ... .18 .66. 1.02. 0.61. 0.33. 0.60. 1 Source: Riverbank Acoustical Laboratories. Test was conducted with 1.50 pcf fiberglass batts and. 2 inch polyisocyanurate foam insulation for the SDI

Section 1 - nysdot

Apr 5, 2010 . designers with the opportunity to reduce the top cover in bridge decks from 3 inches to 2 inches because of their exceptional corrosion resistance. The reduction of cover and slab thickness has the potential to decrease bridge deck load enough to reduce the size or number of girders. Solid stainless steel..

Corrugated Steel Decking, B Deck - FS Industries

Corrugated Steel Decking, B Deck, Mezzanine Decking, , Drill Screw Fasteners, Mezzanine Flooring, Deck Panels, Galvanized B Deck, and Roof Deck from your source for . To calculate price of special lengths, multiply width (3) x special length (in feet) x price per square foot. . 18, All Galvanized, $168.00

Steel Deck - Canam-Buildings

cellular roof and floor deck and metal wall and roof panels and all . (EOF) steel mills, both of which use recycled steel in their manufacturing processes. 2. Our deck manufacturing plants are normally within 500 miles of the job site. Contact your local Canam .. 18 inches (8 inches for N deck, 12 inches for J, H, LS decks)

Standard Codes - irccdd.com

Wood joists or the bottom of a wood structural floor when closer than 18 inches . 2. All wood framing members that rest on concrete or masonry exterior foundation walls and are less than 8 inches (203 mm) from the exposed ground. 3. Sills and sleepers on a concrete or masonry slab that is in direct contact with the

Pds 081 - County of San Diego

Shear walls shall be supported by continuous foundations. (CRC 403.1.2). 3. Concrete slabs-on-grade. Slabs-on-grade shall be minimum 3-. 1/2-inches thick. .. Shear walls shall meet minimum length requirements of CRC R602.10.6.5.1. 17. Cripple wall bracing. Cripple walls shall be braced per CRC. R602.10.11. 18

Deck Framing Connection Guide - Tulalip Tribes

square foot live load plus 10 pounds per square foot dead load), the connection between a deck ledger of pressure preservative-treated Southern. Pine, incised pressure- preservative-treated Hem-Fir or approved decay-resistant species, and a 2-inch nominal lumber band joist bearing on a sill plate or wall plate shall

second generation precast deck panel (nudeck) - DigitalCommons .

2. Government Accession No. 3. Recipient's Catalog No. 1. Title and Subtitle. Second Generation Precast Deck Panel (NUDECK) System. 2. Report Date. December, 2010. 3. ... 1.4.3.2 Field Engineering Prior to Slab Installation . .. spacing between the pockets ranged from 18 to 24 inches; however, there is research

Formwork - Wikipedia

Formwork is temporary or permanent molds into which concrete or similar materials are poured. In the context of concrete construction, the falsework supports the shuttering molds. Contents. [hide]. 1 Formwork and concrete form types; 2 Slab formwork (deck formwork). 2.1 History; 2.2 Timber beam slab formwork; 2.3..

Specs - Roof Deck, Inc.

RDI form decks are available in 9/16, 1-5/16 and 1-1/2 inch deep profiles to serve as either a structural support for lightweight insulating fills or a form for reinforced structural concrete slabs. These products are available in varying material thicknesses and a galvanized finish to offer the design profession a variety of choices

Reinforced concrete slab systems on steel decks

i n f o rc e m e n t . Reinforced concrete slab systems on steel decks. Decking can serve as form, shoring and finished surface. 18 gage. 20 gage. 22 gage. Slab. Thickness,. Simple. Continuous. Simple. Continuous. Simple. C o n t i n u o u s inches. Span. Span. Span. Span. Span. Span. 3. 8-0. 9-0. 7-0. 8-0. 6-6. 7-6. 312. 7-6

Verco Floor Deck Catalog - Western Metal Deck

slab due to the mechanical bond between the deck and the concrete thus creating an effective composite slab. FORMLOK deformations and indentions (embossments) have been specifically designed to pro- vide optimal vertical load capacity. PROFILE DESIGNATIONS. Deck for PunchLok II Systems: . PLB FORMLOK..

Plywood Design and Application Guide - PFS·TECO

tolerance of ±1/32-inch of the grademark-specified thickness of 13/16-inch and less and ±5% of the grademark-specified thickness for panels thicker than 13/16-inch. Some mills also produce specialty sizes (e.g., smaller panels for the Japanese market). Panels 1/2-inch thick and thicker are manufactured with a square..

floor deck design guide - ASC Steel Deck

Composite deck. 2 inch nominal depth, 36 inch coverage. 7 foot to 12 foot Optimal Span Range. No Acustadek Option. Least steel weight per square foot floor deck. Meets SDI 2x12 inch standard profile requirements. Reduced composite slab depth compared to. 3WxH-36 and NH-32. Composite deck. 2 inch..

LOK-2 Inch Corrugated Floor decking Metal Panels

Learn more about LOK 2 Inch Corrugated Floor decking metal panels from Creative Building supply. The panels can be custom cut to any size and gauge

Vulcraft Roof Catalog/REV2 - Civil, Environmental and Architectural .

on 3 inch EPS Plaza deck for the SDI. VERTICAL LOADS FOR TYPE 1.5B. Max. Allowable Total (Dead + Live) Uniform Load (PSF). No. of. Deck. SDI Const. . 41. 36. 33. 29. 2. B 20. 7'-9. 132. 109. 91. 78. 67. 59. 51. 46. 41. 36. 33. B 19. 8'-5. 154. 127. 107. 91. 79. 69. 60. 53. 48. 43. 39. B 18. 9'-1. 174. 144. 121. 103. 89. 78

The behavior and analysis of two-way simply supported concrete .

2. Figure 2. Typical building floor construction utilizing cold- formed steel decking with composite support beams. 3. Figure 3. General layout of full-scale slab tests .. area of supplementary reinforcing transverse to deck corrugations, square inches cross-sectional area of steel deck per width b, square inches slab length in y..

ESR-1112 - ICC-ES

used for roof deck construction and as acoustical panels and suspended ceiling tiles. 3.0 DESCRIPTION. 3.1 Tectum I: Tectum I panels are composed of wood fibers impregnated and bound together into slab form with mineral cements. The panels vary in thickness from 1 inch (25 mm) to. 3 inches (76 mm) and have widths..

TB-105 Garage Floor Design Guidelines - Weyerhaeuser

(1) for garages restricted to passenger vehicles accommodating not more than nine passengers, 3,000 pounds acting on an area of 4 ½ inches by 4 ½ inches. (2) for mechanical parking structures without slab or deck that are used for storing passenger vehicles only, 2,250 pounds per wheel. 2009 IRC. 2012 IRC. 2015 IRC

SDI MANUAL OF CONSTRUCTION WITH STEEL DECK

2. Composite Floor Deck. After installation and adequate fastening, floor deck serves several purposes. It (a) acts as a working platform (b) stabilizes the frame (c) serves ... 3 Deep Rib (3DR) - N Other. II. Deck Type (thickness) Gage and inches. 22 (0.0295). 20 (0.0358). 18 (0.0474). 16 (0.0598). Cellular Bottom Plate

Composite Steel Floor Deck-Slabs - Steel Deck Institute

2. H. Except as specifically required by this Standard, ACI 318 shall not be applicable to the design or construction of composite steel deck-slabs. User Note: Refer to Section 1.4.9 of ACI 318. . 18, Steel-Framed Open-Deck Parking .. Panel end out of square shall not exceed 1/8 inch per foot of panel width (10 mm per m)